Yea for Hyde’s ! Christopher fixed the problem !! We have air conditioning again 👏👏😊
Great service Danny fixed the problem 😊 Our AC is Working again !
Taylor was very thorough-cleaning all the equipment and good explanation of what he was doing.
Professional. timely and competent. Fixed system on first visit.
Daniel was the consummate professional. So knowledgeable. Went above and beyond!
Daniel was so great! He took care of checking EVERYTHING and assured me that all is working properly. He was extremely courteous and careful and experienced.
The guys were on time, extremely clean and very professional
Young man was very pleasant and nice to talk with. Went about his work efficiently. Would be pleased o see him back!
Upon arrival found system serial number 5580 (Goodman) calling for cool, but no air coming out of register grand bedroom, upon further inspection, found ductwork to be torn/detached and collapsed, informed clients of my findings, reattached supply duct for temporary cooling and found now some airflow is present in Grande bedroom, also found a system 2 pounds low on R410 with temperature split of 12° added refrigerant add Client sign acknowledgment form and now system is within specifications getting 18° split, will generate options for duct repair and send to client. Also informed client of comfort plans available and will think about it.
Install five bath ventilation fans off of can lights Fan model: https://iaq.na.panasonic.com/ventilation/fans/whisper-thin-led-pick-a-flow
AC Repair Service: Identified and replaced a failing condenser fan motor in a noisy AC unit. Restored quiet, efficient operation and prolonged the system’s lifespan.
AC System Replacement: Replaced an outdated AC unit with a modern, high-efficiency York system. The new installation improved airflow, reduced energy usage, and delivered consistent comfort.
Performed one-time tune-up on (2) 2006 Amana/Goodman r22 split systems (3.5 & 4 ton). Cleared condensation drains from attic (laundry room access). Changed (4) customer supplied filters (sizes noted). Cleaned out electrical compartments. Cleaned condenser coils. Honeywell Smart Color thermostats (9000) working properly. Checked amps, volts, start and run capacitors, refrigerant charges, and temperature splits . Systems are cooling properly at time of service. Homeowner noticed a few registers not putting out air, informed he has damper plates at some registers blocking airflow, recommended having Hyde’s remove registers and remove dampers then reinstall. Due to age of system and the, using r22 Freon, I recommended replacement of full systems before breakdown. Discussed heat pumps, refrigerant changes, etc. went over maintenance plan and benefits vs tuneup.
Performed a cooling maintenance on two split system units. One is a newly installed American standard split system unit. The other is a carrier split system unit check sequence of operations by checking out all electrical and refrigeration levels. At this time, both systems are cooling down the house properly Before arriving temperature inside house was at 88 after leaving the systems lowered by 8 to 12° difference. Cleaned out condensation line and changed. The filter is located inside FAU. Finish maintenance by washing down both condenser unit. Before leaving locked house back up and set thermostat back to 88.
Found bedroom system was low on refrigerant, last may technician came out and charged with 2lbs r410a, advised client of findings and recommended leak search. Went over other options and client chose to recharge unit at this time. Sending leak search estimate via email. Charged system with 3 lbs r410a. System is cooling properly at this time.
Generator does not have 5 feet in front of exhaust, also generator control is not working properly. Does not let me scroll using the arrow keys up and down did not do maintenance due to those issues.
Removed schedule and one touch presets
Performed monthly maintenance in cooling on 2 American standards splits followed Sequence of operation rinsed out filters checked amps voltage capacitors pressures working at range checked inrush was high installed compressor savers on both units cleared condensation lines rinsed condensers down units are working to manufacture specification in cooling
Alex was turned away at the gate. Lisa texted both numbers and left messages advising tech standing by waiting for gate clearance. Alex stood by for over 30 minutes.
Found safety switch at fau had been tripped, full of water. Advised client of findings and cleared drain lines, flushed with water multiple times. System is draining properly at this time.
Upon arrival client stated living area nest thermostat had error code and not working. Client had removed thermostat off wall and back plate off wall. Found 24 volts at wires. Put back plate and thermostat on wall and common wire not showing up. Found wire not connected all the way. Connected and tested
Performed annual maintenance in cooling on 2 Lennox and one trane splits followed Sequence of operation Changed filters checked amps voltage capacitors working at range checked inrush was high installed compressor savers pressures on working Lennox checked pressures on last 4 7950 was flat on Freon. We will be installing new 14 seer cleared condensation lines rinsed condensers down both units are working to manufacture specification in cooling
The work performed involved the installation of two 3 Ton Silver 14 Horizontal Split Heat Pump Systems. This procedure included careful consideration of the specific requirements for optimal operation, ensuring that each system was set up to function efficiently. The installation was carried out with a focus on quality and adherence to industry standards, guaranteeing longevity and reliability in the systems provided.